Thank you for taking an interest in the Circuitbreaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 209-3-1-61F-4-8-10, an item that traces back to the manufacturer Sensata Technologies Inc. Listed with NSN 5925014624825, this listing is available for purchase from our website at any time. If you are interested in part number 209-3-1-61F-4-8-10 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-462-4825 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014624825 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
209-3-1-61F-4-8-10 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
AJEC | Boss Height | 0.220 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 3.108 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 3.550 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 5.125 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 3.550 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.026 INCHES NOMINAL |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.600 MINIMUM AT 125 PCT ALL LOCATIONS AND 5.000 MAXIMUM AT 125 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CMLP | Thread Quantity Per Inch | 32 |
MRC | Decoded Requirement | Clear Text Reply |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote