Thank you for taking an interest in the Circuitbreaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number AP1-M39019 01-216S, an item that traces back to the manufacturer Sensata Technologies Inc. Listed with NSN 5925014831544, this listing is available for purchase from our website at any time. If you are interested in part number AP1-M39019 01-216S and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-483-1544 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014831544 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M39019/01-216S | 3 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.000 AMPERES AC SINGLE LOCATION AND 1.00 AMPERES DC SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION AND 240.0 DC SINGLE LOCATION |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
ADAT | Body Width | 0.656 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 2 THREADED BUSHING |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 1.562 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 SCREW |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.870 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION AND 50.0 DC SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 SINGLE LOCATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.