Thank you for taking an interest in the Circuitbreaker NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number ET74422, an item that traces back to the manufacturer Spd Electrical Systems Inc. Listed with NSN 5925000638997, this listing is available for purchase from our website at any time. If you are interested in part number ET74422 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 75.0 AMPERES AC AND 75.0 AMPERES DC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRJ | Special Handling Feature | MAGNETIC |
CBBL | Features Provided | ADJUSTABLE TRIP RELEASE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC AND 10000.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
ABMK | Overall Width | 4.875 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPSF | Adjustable Trip Setting Current Range Per Pole In Amps | +900.0/+1050.0 AC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
ABHP | Overall Length | 6.500 INCHES NOMINAL |
AAQL | Body Style | |
ABKW | Overall Height | 4.125 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | AIR |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 500.0 AC AND 250.0 DC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 600 PCT AND 32.000 MAXIMUM AT 600 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.190 INCHES NOMINAL |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
TTQY | Terminal Type And Quantity | 6 QUICK DISCONNECT, FEMALE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.