Thank you for taking an interest in the Switch Thermostatic NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number VE2-146-1DEGC, an item that traces back to the manufacturer Spx Corporation. Listed with NSN 5930007417860, this listing is available for purchase from our website at any time. If you are interested in part number VE2-146-1DEGC and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-741-7860 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 007417860 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
G330084S2 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.688 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.375 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.750 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | SLOT |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE,PRESET AND ACTUATION POINT ADJUSTABLE,PRESET |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CTYX | CONTACT STIMULUS RATING | 146.10 ACTUATION POINT NOMINAL DEGREES CELSIUS AND 143.10 DEACTUATION POINT NOMINAL DEGREES CELSIUS AND 3.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL THIRD VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.125 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.500 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
CTYM | CONTACT ADJUSTMENT RANGE | -55.00 TO 150.00 ACTUATION POINT DEGREES CELSIUS AND-52.00 TO 162.00 DEACTUATION POINT DEGREES CELSIUS |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |