Thank you for taking an interest in the Transformer Power Autotransforme NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number A401-02, an item that traces back to the manufacturer Superior Teletec Transmission. Listed with NSN 5950006478505, this listing is available for purchase from our website at any time. If you are interested in part number A401-02 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-647-8505 Item PartTypeName: TRANSFORMER,POWER AUTOTRANSFORME | 5950 | 006478505 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
B17300-03REVD | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.686 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.339 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 6.264 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY,FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 943.6 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRMJ | WINDING POWER RATING | 28.3 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SCREW |