Thank you for taking an interest in the Transformer Power NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number TTI-12201, an item that traces back to the manufacturer Transformer Technicians Inc. Listed with NSN 5950011419121, this listing is available for purchase from our website at any time. If you are interested in part number TTI-12201 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-141-9121 Item PartTypeName: TRANSFORMER,POWER | 5950 | 011419121 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
25P228032-01 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ADAQ | BODY LENGTH | 7.380 INCHES MINIMUM AND 7.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.380 INCHES MINIMUM AND 3.500 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.5 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 101.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.40 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 6.54 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.54 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 8 SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD |