Thank you for taking an interest in the Generator Set Steam Turbine NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number LJ91000, an item that traces back to the manufacturer Turbodyne. Listed with NSN 6115009656561, this listing is available for purchase from our website at any time. If you are interested in part number LJ91000 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6115-00-965-6561 Item Description: Generator Set Steam Turbine | 6115 | 009656561 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Lj91000 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAXX | MOUNTING TYPE | BASE |
AAYL | STEAM OPERATING PRESSURE | 1050.0 POUNDS PER SQUARE INCH GAGE |
ABHP | OVERALL LENGTH | 141.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 154.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 72.000 INCHES NOMINAL |
ACDC | III CURRENT TYPE | AC |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AFHS | ACCESSORY COMPONENT QUANTITY | 1 |
AJAA | STEAM TEMP RATING | 940.0 DEG FAHRENHEIT |
AKVY | ACCESSORY CONTROLLING AGENCY | ELECTRIC MACHINERY MFG CO. |
AKVZ | ACCESSORY IDENTIFYING NUMBER | ELECTRIC MACHINERY DWG NO. 359B016 |
AMSB | IDENTIFYING NUMBER | DWG NO. 140B085 |
AQGA | MANUFACTURER NAME | ELECTRIC MACHINERY CO |
AWNT | STAGE TYPE | MULTIPLE |
AYGY | AC WATTAGE RATING | 1500.0 WATTS |
AYHB | LINE TO LINE VOLTAGE IN VOLTS | 450.0 |
AYHD | POWER FACTOR IN PERCENT | 0.8 |
AYHE | EXCITOR TYPE | SELF-EXCITED |
AYHF | EXCITOR | NOT INCLUDED |
AZBN | PRIME MOVER MANUFACTURER NAME | WORTHINGTON CORP |
AZBQ | TURBINE DESIGN TYPE | IMPULSE |
AZBR | EXHAUST TYPE | CONDENSING |
AZBS | TURBINE TO GENERATOR COUPLING METHOD | GEAR TRAIN |
AZCG | ACCESSORY COMPONENT NAME | STATIC EXCITATION AND VOLTAGE REGULATION SYSTEM |
AZCL | AMBIENT TEMP IN DEG CELSIUS | 50.0 |
AZCM | TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 100.0 |
FAAZ | PHASE | THREE |