Thank you for taking an interest in the Switch Thermostatic NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number NF9-20022, an item that traces back to the manufacturer United Electric Controls Company. Listed with NSN 5930010466942, this listing is available for purchase from our website at any time. If you are interested in part number NF9-20022 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-046-6942 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 010466942 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
222-10NL-2222586 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 4.875 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.281 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.875 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.500 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.625 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.750 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AWTN | OPERATING TEMP RATING | 245.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 140.00/215.00 ACTUATION POINT DEGREES FAHRENHEIT AND 138.00 TO 210.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
FEAT | SPECIAL FEATURES | MANUFACTURING PROCESSES AND MATERIALS ARE CRITICAL TO SAFETY OF LIFE AND PROPERTY |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | RECTANGULAR |