Thank you for taking an interest in the Regulator Engine Generator NSN parts that we carry here on Buy Military Ground Vehicle Parts. You have reached the RFQ page for part number 391941, an item that traces back to the manufacturer White Motor Corp. Listed with NSN 2920002554938, this listing is available for purchase from our website at any time. If you are interested in part number 391941 and wish to learn more, be sure to fill out and submit the RFQ form found on this page. By presenting us information such as your target price and expected delivery date, we can best formulate and present a solution that closely caters to your unique needs and restrictions alike.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
2920-00-255-4938 Item PartTypeName: REGULATOR,ENGINE GENERATOR | 2920 | 002554938 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9MI310P1 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARA | TERMINAL QUANTITY | 3 AND 1 |
AARB | TERMINAL TYPE | THREADED STUD AND SCREW |
ABTB | MOUNTING HOLE DIAMETER | 0.328 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.328 INCHES NOMINAL |
ABVG | MOUNTING SLOT LENGTH | 0.433 INCHES NOMINAL |
ADER | MOUNTING STYLE | TWO PLAIN HOLES TWO SLOTTED HOLES |
ADNY | DISTANCE BETWEEN HOLES ALONG LENGTH | 5.312 INCHES NOMINAL |
AGBC | SHOCK MOUNT | NOT PROVIDED |
ALBH | RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 7.0 MINIMUM AND 7.7 MAXIMUM |
ANYC | SYSTEM VOLTAGE RATING | 6.0 |
ANYD | SYSTEM GROUND POLARITY | POSITIVE |
ANYE | VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |
ANYH | VOLTAGE REGULATOR UNIT QUANTITY | 1 |
ANYJ | CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
ANYK | CURRENT REGULATOR UNIT QUANTITY | 1 |
ANYP | OUTPUT CURRENT RATING IN AMPS | 23.0 MINIMUM AND 27.0 MAXIMUM |
ANYR | CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
ANYS | CUT-IN VOLTAGE RATING | 5.9 MINIMUM AND 6.8 MAXIMUM |
ANZB | REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
ANZC | FIELD RELAY UNIT | NOT INCLUDED |
ANZE | TERMINAL ENCASEMENT | NOT ENCASED |
APAT | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES ALONG LENGTH | 5.312 INCHES NOMINAL |
APAW | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES AND PLAIN HOLES ALONG WIDTH | 6.000 INCHES NOMINAL |